Description: Invalid command line syntax was detected.
System action: Operation terminates
User response: Correct the command line and try again
Module: seelistener
LS0006I Response received for:
session id
Description: A response for the given session id was received.
System action: none
User response: none
Module: seelistener
LS0007I Worker thread starting for
protocol on port
port
Description: The worker thread for the given protocol and port was started.
System action: none
User response: none
Module: seelistener
LS0008E Unable to create protocol handler:
exception message
Description: An exception occurred.
System action: none
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0009W Port configuration in seelistener.exe.config ignored as option '-region' specified
Description: The port configuration in the configuration file was overridden by the -region parameter. The listener will
listen on its default ports and send all requests to the specified region.
System action: none
User response: none
Module: seelistener
LS0014E An exception occurred:exception message
Description: An exception occurred.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0017I
protocol name Listener starting on port
port number ,
Description: A listener is starting on the given port for the specified protocol.
System action: none
User response: none
Module: seelistener
LS0019E Exception in protocol handler:
exception message
Description: An exception occurred.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0020I SEE listener shutting down
Description: The listener is shutting down.
System action: none
User response: none
Module: seelistener
LS0021W The "-was" option is ignored if "-dispatcher:URL" is specified.
Description: Invalid command line syntax was detected.
System action: Operation terminates
User response: Correct the command line and try again
Module: seelistener
LS0023I
conversation type listener channel closing
Description: The specified listener channel is closing.
System action: none
User response: none
Module: seelistener
LS0024E A
exception type exception occurred while submitting a console message to region
region name:
exception message The message was:
console message that could not be submitted
Description: An exception occurred.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0025W TN3270 conversation
conversation ID: Discarding NVT data from client
Description: The client sent non-3270 data, which is currently not supported. The data has been discarded.
System action: none
User response: none
Module: seelistener
LS0026E TN3270 conversation
conversation ID: Illegal sequence in TN3270E header (x'FF0:X2')
1 = invalid byte in hex
Description: A TN3270 protocol error occurred.
System action: The conversation is terminated
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0027E TN3270 conversation
conversation ID : Negotiation failed (description of negotiation stage), terminating conversation
Description: TN3270 negotiation failed.
System action: The conversation is terminated
User response: none
Module: seelistener
LS0028E
protocol name conversation
conversation ID: Unexpected exception (description of where exception occurred)
exception message
Description: An exception occurred.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0030W Invalid value
invalid heartbeat value specified for heartbeat ignored
Description: An invalid value was specified during a heartbeat request.
System action: Operation terminates
User response: none
Module: seelistener
LS0033E
protocol name conversation
conversation ID: unable to send data: conversation ended
Description: A protocol error for the specified protocol occurred.
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0035I Shutdown initiated
Description: The listener has been asked to shut down.
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0039E Unable to process configuration file "filename"
Description: The specified configuration file could not be processed.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0040W Channel "channel name" has an invalid
attribute name attribute - skipping it
Description: An error in the configuration has been detected.
System action: none
User response: Fix the configuration file
Module: seelistener
LS0041E Service installation failed:
exception
Description: An exception occurred.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0042E Service uninstallation failed:exception
Description: An exception occurred.
System action: Operation terminates
User response: Check the console log and
Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
Module: seelistener
LS0043I Listener service installed
Description: The listener service was installed.
System action: none
User response: none
Module: seelistener
LS0044I Listener service uninstalled
Description: The listener service was uninstalled.
System action: none
User response: none
Module: seelistener
LS0045E Invalid parameter for service installation "command-line parameter"
Description: Invalid command line syntax was detected.
System action: Operation terminates
User response: Correct the command line and try again
Module: seelistener
LS0046E -service_username and -service_password must be specified with -service_account:user
Description: Invalid command line syntax was detected.
System action: Operation terminates
User response: Correct the command line and try again
Module: seelistener
LS0047E -service_username and -service_password are only allowed with -service_account:user
Description: Invalid command line syntax was detected.
System action: Operation terminates
User response: Correct the command line and try again
Module: seelistener
LS0048W Unable to create Windows event log source for the listener service:
details
Description: The listener could not create a Windows event log source to emit events to.
System action: Events will not be logged to the event log
User response: Make a note of any details, and attempt to rectify the problem
Module: seelistener
LS0049E
protocol name
conversation
conversation ID internal error:
description
Description: An error occurred in the specified conversation.
System action: The conversation is terminated
User response: Make a note of the error, and attempt to fix it
Module: seelistener
LS0050W TN3270 conversation
conversation ID: Unsupported TN3270E data type
data type value - discarding record
Description: An invalid TN3270 data type was received in the conversation.
Description: An error was detected during negotiation.
System action: the error is ignored
User response: none
Module: seelistener
LS0054I TN3270 conversation
conversation ID: Received
"DO", "DON'T", "WILL", or "WON'T" for unrecognized option
option code, replying with
"WON'T" or "DON'T"
Description: An unrecognized option code was received.
System action: none
User response: none
Module: seelistener
LS0055W
protocol name conversation
conversation ID timed out waiting for client
Description: A protocol timeout occurred.
System action: none
User response: none
Module: seelistener
LS0056W TN3270 conversation
conversation ID: Discarding
data length bytes of non-record outbound data
Description: the specified number of bytes was discarded in the conversation.
System action: Bytes are discarded
User response: none
Module: seelistener
LS0057E
protocol name conversation
conversation ID: Terminal autoinstall failed
message
Description: The terminal auto install failed.
System action: The conversation with the client is terminated
User response: Make a note of the error message and attempt to rectify based on its content
Module: seelistener
LS0058I
protocol conversation
conversation number (termid "terminal id") on channel "channel name" from
client address
Description: Information about a conversation. This message may be displayed before other messages about the conversation,
to identify the client system and other parameters.
System action: none
User response: Make note of the message if you are investigating other issues related to the listener
Module: seelistener
LS0059W TN3270 conversation
conversation ID: Proceeding with invalid device type "device type string"
Description: An invalid device type was detected.
System action: Processing continues
User response: none
Module: seelistener
LS0060E Unexpected null response encountered
Description: An unexpected null response was detected.